Using the Reading Protocol Editor From Viewer
Introduction
Use the reading protocol editor to change DICOM or viewport properties to select series for display in a user reading protocol.
When you access the reading protocol editor from Viewer, the available list of DICOM options depends on the series modality and your selection of the following options:
- Image Type
- Series Contains
- Contrast
- Image Orientation
- Image Preset
Steps
- Select Edit Reading Protocol from either location:
Location |
Use this option ... |
---|---|
From the Viewer. |
Select Edit Reading Protocol from the Reading Protocol Selection Drop-Down menu. See Viewer Toolbar Features. |
From the Save Reading Protocol dialog box (located in the Reading Protocol Selection Drop-Down menu). |
Select Edit Reading Protocol. |
- Optional: Automatically create additional steps so all the images in the study are available in reading protocol steps. Note: Available for all modalities except MG.
- Click the Reading Protocol Step drop-down menu located on the reading protocol editor toolbar. See Reading Protocol Editor Toolbar.
- Select Organize Steps. A dialog box displays.
- Select the Automatically create steps check box.
- Click Update.
- Change some, all, or none of these viewport options:
If you want to do this... |
Complete these steps... |
---|---|
Determine what displays in the viewport: Empty, All Images, Bookmark Images, or Series. Note: Synapse displays additional options when you select Series. |
From the Type drop-down list, select an option. |
Determine if a current or prior (such as P1 and P2) series displays in the selected viewport. |
From the Study Reference drop-down list, select an option. |
Change the tile format for the selected viewport. See Changing the Number of Images in a Viewport with Tile Format. |
From the Tile Format drop-down list, select an option. |
Apply an interactive tools, such as zoom, to all of the images in the series or to the selected image in the series. |
From the Apply Tool To drop-down list, select an option. |
Apply a selected zoom factor to a series. |
From the Initial Zoom drop-down list, select an option. Note: You must calibrate your monitor in order for some Initial Zoom options to work. See Calibrating Monitors for True Size Image Display |
Enable or disable text overlay information for all the series in a study. |
From the Text Overlays drop-down list, select an option. |
Determine which index displays in the selected viewport. Note: The Index option is not available unless you remove the Series Contains option. |
In the Index text box, change the index number. |
Determine the step increment. The increment is typically the number of viewports in the reading protocol step. If you change the increment number, some series might not display using this reading protocol. Note: The Index / Increment option is not available unless you remove the Series Contains option. Additionally, the Increment option is not available unless the Reading Protocol step has the Automatically create steps option enabled. |
In the Increment text box, change the increment number. |
- Click the plus sign
below the last option. Synapse displays a drop-down list
.
- Click the down arrow to display the following options.
If you want to do this... |
Complete these steps... |
---|---|
Search the series description based on the first three characters of each word in the series description as displayed in the text box or you can manually enter text. For example, if the series description contains the term sagittal, Synapse uses the first three letters, sag, to match other sagittal descriptions. If another series description contains the term sagittal spelled as sagital, Synapse still matches the misspelled sagital series description with this user created reading protocol. |
|
Match against the image type in the DICOM properties of the image. Note: The number of Image Type Value options depends on the image. |
|
Match against the orientation of the patient: sagittal, coronal, or transverse (axial). |
|
Match against the DICOM contrast tag. |
|
Apply a preset to the series. See Applying a Preset to an Image. |
|
- Optional: For some DICOM properties, Synapse provides an additional option Rules Target so that the reading protocol can match different series with same DICOM properties. Do either of the following:
If you want to do this... |
Choose this option... |
---|---|
Display the same series in each viewport that matches the DICOM properties. |
|
Display different series in each viewport that match the DICOM properties. If no matching series are available, Synapse displays an empty viewport. |
|
Note: |
|
- Repeat steps 4 and 5 until you have all the options you want.
- Optional: to remove an added viewport option, click the Minus sign
.
- Do one of the following:
If you want to do this... |
Choose this option... |
---|---|
Review your changes in the Viewer before saving the reading protocol. |
|
Save the reading protocol. |
|
Return to the Viewer without saving the reading protocol changes. |
|
Related Topics
Reading Protocol Editor Toolbar
Organizing Reading Protocol Steps