Opening an MG CAD Structured Report
Introduction
When an MG CAD SR (structured report) is available for a study, Synapse displays MG CAD SR and text overlay
information on the image, such as Study:CAD
succ with findings.
When you open a study, the text overlay indicates if there are CAD finding for that study. Once you enable or show the CAD findings, Synapse updates the text overlay for each image to indicate that whether there are CAD findings on the image level, such as:
- Image: CAD succ with findings
- 2/4
Where the 2 indicates there are two CAD findings on the image and the 4 indicates the total number of findings for the study.
When you hover over an MG CAD SR finding, Synapse displays the following information:
- Type of finding, such as a calcification cluster
- CAD manufacturer name
- CAD manufacturer software name and version
Note: |
|
You can show or hide a MG CAD SR, but you cannot edit or move an MG CAD SR finding. When you magnify an image, the MG CAD SR changes proportionally.
To automatically display the MG CAD SR when you open a study, see Configuring Mammography Settings.
Steps
- Right-click the image to display the image context menu.
- Select Display Formats> CAD Findings.
- If the study contains CAD findings, Synapse displays the CAD annotations.
- If more than one MG CAD SR exists for a study, scroll to the image.
- Optional: To hide the MG CAD structured report finding, select Display Formats> CAD Findings again.
Additional Options
Use any one of the following options to toggle the MG CAD SR on or off:
- Click MG CAD SR
to display or hide the finding.
- See Keyboard Shortcuts for MG.
- See Configuring Mammography Settings
- See Active Overlays for MG