Enabling IntelliScroll
Introduction
You can manually enable or disable IntelliScroll for a particular study. When the session ends for that study, Synapse reverts to the IntelliScroll User Setting.
For CT, PT, and MR modalities, Synapse automatically enables IntelliScroll using the Same FOR option.
Prerequisite
The series in the study that have the same Frame of Reference (FOR) are automatically linked. If the series do not have the same FOR, you can use Same Orientation option. You can use the delta link option to change the delta for a series (this does not apply to MG series that use SyncPrior).
Steps
- Right-click the image to display the image context menu.
- Select IntelliLink/Scroll > IntelliScroll to enable IntelliScroll. Synapse highlights IntelliScroll on the context menu to indicate IntelliScroll is active.
- Do any of the following:
If you want to ...
Do this ...
Cycle through the IntelliScroll link modes.
Select IntelliLink/Scroll > IntelliScroll - Cycle link mode.
Disable the IntelliScroll option for all displayed series.
Select IntelliLink/Scroll > IntelliScroll - Remove All.
Enable auto link scrolling for series with the same FOR.
Select IntelliLink/Scroll > IntelliScroll - Same FOR.
Enable auto link scrolling for series with the same orientation.
Select IntelliLink/Scroll > IntelliScroll - Same Orientation.
Enable IntelliScroll to scroll by image index.
Select IntelliLink/Scroll > IntelliScroll - SyncIndex.
(For Mammography studies only) Enable IntelliScroll to synchronize by prior when scrolling between series images during current and prior MG studies comparisons.
Select IntelliLink/Scroll > IntelliScroll - SyncPrior.
- Click on a series and use the mouse wheel to scroll multiple series
simultaneously.
Note:
For Mammography studies, the IntelliScroll-SyncPrior mode is the default action when the IntelliScroll > MG option is selected from the User Settings. This feature synchronizes the scrolling of images from prior studies to compare with the current study.
- Optional: If you want to change the delta for a linked series,
do any of the following:
Note:
This does not apply to MG series that use SyncPrior.
If you want to ...
Do this ...
Create an automatic delta.
Use manual delta with the delta link icon.
- Click the IntelliScroll active
overlay until the delta link active overlay
displays.
- Use the mouse wheel to scroll to the correct delta.
Use manual delta with the alt key.
- Put your cursor in the viewport of the series you want to adjust.
- Press and hold the alt key.
- Use the mouse wheel to scroll to the correct delta.
- Release the alt key. All linked series scroll synchronously.
Create a manual delta when IntelliScroll is disabled.
- Ensure IntelliScroll is disabled the context menu IntelliLink/Scroll > IntelliScroll-Remove all.
- Scroll the series to the correct delta.
- Enable IntelliScroll in one
of the following ways:
- IntelliLink/Scroll > IntelliScroll - Same FOR
- IntelliLink/Scroll > IntelliScroll - Same Orientation
- Click the IntelliScroll active
overlay until the delta link active overlay
Additional Options
Use any one of the following options to enable or disable IntelliScroll:
- See Viewer Context Menu and Icon Menu Options for a list of IntelliScroll menu icon options.
- See Keyboard Shortcuts for IntelliLink and IntelliScroll.
- See Active Overlays for IntelliScroll.
- See Configuring IntelliScroll Settings
Related Topics
Viewer Context Menu and Icon Menu Options